Agreement and reasons for disagreement between photographic and hospital biomicroscopy grading of diabetic retinopathy

Sallam, A, Scanlon, Peter H ORCID: 0000-0001-8513-710X, Stratton, I M, Jones, V, Martin, C N, Brelen, M and Johnston, R L (2011) Agreement and reasons for disagreement between photographic and hospital biomicroscopy grading of diabetic retinopathy. Diabetic Medicine, 28 (6). pp. 741-746. doi:10.1111/j.1464-5491.2011.03273.x

Full text not available from this repository.

Abstract

Aims - To compare agreement level and identify reasons for disagreement between grading of mydriatic digital photographs in a diabetic retinopathy screening service and hospital eye service biomicroscopy grading. Methods - Structured examination findings leading to automatically calculated National Screening Committee grades recorded on an electronic medical record system in the hospital eye service at the first clinic visit after diabetic retinopathy screening service referral between April 2006 and November 2007 were retrospectively compared with the grade at the screening visit that prompted referral. In cases of disagreement, screening images were reviewed. Results - Data on 452 eyes (226 patients) were analysed. For retinopathy, hospital eye service slit-lamp biomicroscopy grades were: R0 (no diabetic retinopathy) in 63 eyes; R1 (background retinopathy) in 251eyes; R2 (pre-proliferative) in 129 eyes and R3 (proliferative) in nine eyes. Diabetic retinopathy screening service grades were in agreement in 350 eyes (77.4%), showed a lower grade in 59 eyes and a higher grade in 43. Agreement was moderate (κ = 0.60). The most common reason for disagreement was overgrading of R1 by clinicians. Hospital eye service biomicroscopy maculopathy grades were: M0 (no maculopathy) in 366 eyes and M1 (maculopathy) in 86 eyes. Diabetic retinopathy screening service grades were in agreement in 327 eyes (72.3%), showed a lower grading in five eyes and a higher grade in 120 eyes. Agreement was moderate (κ = 0.41). The commonest cause for disagreement was clinicians failing to identify fine macular exudates. Conclusions - This study of routine clinical services demonstrates moderate agreement between non-medical grading of mydriatic digital retinal photography images and hospital slit-lamp biomicroscopy grading of patients referred with diabetic retinopathy. The majority of errors in grading were attributable to errors by hospital doctors, usually in the direction of under-grading which could be a potential source of clinical risk if treatment is delayed.

Item Type: Article
Article Type: Article
Uncontrolled Keywords: diabetes mellitus;diabetic retinopathy;digital photographs;maculopathy;screening
Subjects: R Medicine > RA Public aspects of medicine > RA645.A-Z Individual diseases or groups of diseases, A-Z > RA645.D54 Diabetes
R Medicine > RE Ophthalmology
Divisions: Schools and Research Institutes > School of Education and Science
Research Priority Areas: Health, Life Sciences, Sport and Wellbeing
Depositing User: Denise Cain-Jones
Date Deposited: 12 Oct 2015 09:15
Last Modified: 31 Aug 2023 09:10
URI: https://eprints.glos.ac.uk/id/eprint/2676

University Staff: Request a correction | Repository Editors: Update this record

University Of Gloucestershire

Bookmark and Share

Find Us On Social Media:

Social Media Icons Facebook Twitter YouTube Pinterest Linkedin

Other University Web Sites

University of Gloucestershire, The Park, Cheltenham, Gloucestershire, GL50 2RH. Telephone +44 (0)844 8010001.