Development, validation and test-retest reliability of a load cell-based device for assessment of isometric forearm rotation torque

Köykkä, Miika ORCID logoORCID: https://orcid.org/0000-0003-0451-9099, Laatikainen-Raussi, Iida ORCID logoORCID: https://orcid.org/0009-0008-9258-4010, Vierola, Sami, Cronin, Neil J ORCID logoORCID: https://orcid.org/0000-0002-5332-1188, Waller, Benjamin ORCID logoORCID: https://orcid.org/0000-0002-0738-0670 and Vänttinen, Tomi ORCID logoORCID: https://orcid.org/0009-0007-5813-6583 (2025) Development, validation and test-retest reliability of a load cell-based device for assessment of isometric forearm rotation torque. Physiological Measurement, 46 (8). 08NT01. doi:10.1088/1361-6579/adf488

[thumbnail of 15226 Köykkä et al (2025) Developement, validation and test re-test reliability.pdf]
Preview
Text
15226 Köykkä et al (2025) Developement, validation and test re-test reliability.pdf - Published Version
Available under License Creative Commons Attribution 4.0.

Download (1MB) | Preview

Abstract

Abstract Objectives. This study aimed to develop and validate a load cell-based device for measuring isometric forearm rotation torque and to determine its test-retest reliability. Approach. The custom-built device was calibrated using known weights and validated against a high-precision torque transducer. For reliability assessment, 35 physically active participants (20 males, 15 females; age 30 ± 7 years) were tested for isometric forearm pronation and supination strength 5–7 d apart. Main results. The custom device demonstrated excellent validity (intraclass correlation coefficient (ICC), absolute agreement = 1.00; r 2 = 1.00, p < 0.001; mean difference = −1.26–1.44%, p < 0.001). Test-retest reliability was excellent for absolute pronation and supination torque (ICC = 0.88–0.97; coefficient of variation percentage (CV%) = 4.1–5.6; minimal detectable change (MDC) at 90% confidence level = 13.1–19.9%), good to excellent for supination:pronation ratios (ICC = 0.60–0.88; CV% = 7.0–8.6; MDC = 0.10–0.13), and fair to good for dominant:non-dominant ratios (ICC = 0.42–0.66; CV% = 6.1–7.6; MDC = 0.07–0.10). Sex significantly influenced absolute torque values, with males demonstrating consistently higher torque, although reliability metrics were similar for both sexes. Significance. The device is valid, and the test is reliable. It is suitable for clinical assessments, rehabilitation monitoring, and performance evaluation, facilitating an improved understanding of factors affecting elbow overloading and injuries. Limb ratio metrics should be interpreted with caution due to their lower reliability.

Item Type: Article
Article Type: Article
Subjects: Q Science > QP Physiology
Divisions: Schools and Research Institutes > School of Education, Health and Sciences
Depositing User: Charlotte Crutchlow
Date Deposited: 11 Aug 2025 09:16
Last Modified: 20 Aug 2025 08:00
URI: https://eprints.glos.ac.uk/id/eprint/15226

University Staff: Request a correction | Repository Editors: Update this record

University Of Gloucestershire

Bookmark and Share

Find Us On Social Media:

Social Media Icons Facebook Twitter YouTube Pinterest Linkedin

Other University Web Sites

University of Gloucestershire, The Park, Cheltenham, Gloucestershire, GL50 2RH. Telephone +44 (0)844 8010001.